ABB低壓電容補償柜的作用及組成結構解析
ABB低壓(ya)電(dian)容補償(chang)柜主(zhu)要作用是提高電(dian)力系(xi)統(tong)(tong)的(de)(de)功率因(yin)數,降低系(xi)統(tong)(tong)的(de)(de)無功功率,從而優化(hua)電(dian)能(neng)的(de)(de)使用。其主(zhu)要功能(neng)在于補償(chang)無功功率,改善功率因(yin)數,穩定系(xi)統(tong)(tong)電(dian)壓(ya),減少電(dian)能(neng)浪(lang)費。
以下(xia)是對ABB低壓電(dian)容柜的基礎介紹:
⑴作用:
ABB低(di)壓(ya)電容柜在(zai)正常配(pei)電系統運行中(zhong)通過自動分步投切并(bing)聯(lian)在(zai)配(pei)電變壓(ya)器1kV及以下(xia)母線的電容器組,提供容性無(wu)(wu)功(gong)功(gong)率,補償感性無(wu)(wu)功(gong)功(gong)率,從而(er)減少(shao)電壓(ya)和無(wu)(wu)功(gong)功(gong)率波(bo)動,降低(di)線路(lu)損耗,提高(gao)變壓(ya)器傳(chuan)輸(shu)(shu)容量,提高(gao)電力傳(chuan)輸(shu)(shu)效率。同時,它具備(bei)負荷監測功(gong)能,實時監測電網運行狀(zhuang)況(kuang),實現(xian)無(wu)(wu)功(gong)補償和配(pei)電監測的一體(ti)化。
⑵結構:
ABB低(di)壓(ya)電(dian)(dian)(dian)容補(bu)償裝置通(tong)常包括電(dian)(dian)(dian)抗(kang)(kang)器(qi)(qi)(qi)、電(dian)(dian)(dian)容器(qi)(qi)(qi)、隔離開(kai)關(guan)、熔斷器(qi)(qi)(qi)、接觸(chu)(chu)器(qi)(qi)(qi)、電(dian)(dian)(dian)流(liu)(liu)互感器(qi)(qi)(qi)、快熔等二次元(yuan)件(jian)。一個(ge)典型的(de)低(di)壓(ya)電(dian)(dian)(dian)容補(bu)償柜包括電(dian)(dian)(dian)抗(kang)(kang)器(qi)(qi)(qi)、電(dian)(dian)(dian)容器(qi)(qi)(qi)、接觸(chu)(chu)器(qi)(qi)(qi)、熔斷器(qi)(qi)(qi)等組(zu)件(jian)。通(tong)過(guo)監測進線柜電(dian)(dian)(dian)壓(ya)和(he)(he)電(dian)(dian)(dian)流(liu)(liu)的(de)相位差,控(kong)制器(qi)(qi)(qi)輸出控(kong)制信號(hao),控(kong)制交流(liu)(liu)接觸(chu)(chu)器(qi)(qi)(qi)的(de)閉合(he)和(he)(he)斷開(kai),實(shi)現電(dian)(dian)(dian)容器(qi)(qi)(qi)的(de)投入和(he)(he)退出。
⑶使用條件:
最(zui)高(gao)運(yun)行電壓≤1.1Un;
最大過載電流≤1.31 n;
周圍環境溫度(du)-25~+45℃;
室內相對濕度不(bu)超過90% (溫度為25℃時);
安裝地點海(hai)拔高度不超過2000m;
無劇烈振動,垂直傾(qing)斜度不超過(guo)5度;
無(wu)導電性(xing)塵(chen)埃(ai)、火(huo)災、爆炸危險(xian);
無足以腐蝕金屬和破壞絕(jue)緣的氣體(ti)。
ABB低壓電容補償柜可分為自動補償裝置和動態補償裝置,根據補償對象的不同。在選擇電容補償裝置時,需要考慮系統和負載的性質、大小、阻抗特性、運行方式等多方面因素,以上是得潤電氣對電容柜基礎(chu)知(zhi)識(shi)的簡要梳理。
掃(sao)一掃(sao)二維碼了解更(geng)多詳情:
得潤電氣訂閱號(hao)
得潤(run)電氣頭條(tiao)號